Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13656076

- Product Categories
- Friendly Links
Information Name: | Rotary dehumidification unit _ units _ air conditioning units, dehumidifiers |
Published: | 2015-06-07 |
Validity: | 0 |
Specifications: | Any |
Quantity: | |
Price Description: | |
Detailed Product Description: | Rotary dehumidifier works ?? Unit 1, desiccant wheel manufacturing temperature is above 500 ℃ ceramic fiber paper into a honeycomb after forming mechanism via the rotary dehumidifier unit, then applied between the ceramic fibers and silica too, so it does not burn and hygroscopic desiccant wheel and other problems. Because of its dehumidification function is to use a physical effect, rather than chemical action, and therefore do not produce any harmful chemicals. 2, dehumidification principle wheel dehumidifier system by coating silica on the wheel in the air moisture physically adsorbed on the synthesis of a porous silica gel, and then turning the regeneration zone, adsorbed on silica gel gas heating vaporized water holes, to exchange heat exchanger at the entrance to a high temperature and humidity of air heat recovery units, followed by cold and wet through indoor air has been cooled in a heat exchanger to cool, since the dew point difference from Condensate discharge. 3, the cooling and dehumidifying principle: Because the air at different temperatures and energies, moisture air can hold is different, the moisture content in the air with the decrease of air temperature decreases. When the outdoor air through the fresh air cooler, the air is cold pipe cooling table cool air as the temperature decreases, water vapor in the air condenses gradually and reach saturation point, when the dew point of the air continues to decline, the air in steam becomes condensate and precipitation, so that the absolute water content in the air unit is reduced, to achieve the air dehumidification process. 4. Adsorption Rotary Dehumidification principle: the desiccant wheel dehumidification section within a sealing system is divided into treated areas and regeneration area, slowly rotating desiccant wheel to 8-10 rev / h speed, to ensure a continuous whole dehumidification process. When the process air through the treatment zone runner, in which the water vapor is adsorbed moisture runner in the media, while vapor phase transition, and the release of latent heat, moisture runner but also because some of the water and gradually moving saturation; in this case, the process air because of their moisture reduction and latent heat release and become dry, hot air. Rotary heat recovery air handling units runner fresh air heat recovery units with high efficiency, and low cross-contamination, and can be combined with different air conditioning into one, reduce the room occupied by the location and installation costs. Heat exchange principle cellular wheel low speed in the direction indicated by the arrow is rotated in winter as an example: return air chamber through the upper part of the heat exchanger, and discharged to the outside, at this time, most of the exhaust gas contained in the heat and moisture accumulation in the wheel, the discharged only to be polluted outdoor air. In addition, heat from outdoor air lower half of the points introduced by the runner, gets runner in the build up of heat and moisture, is preheated humidified. Similarly, pre-cooling, dehumidification effect during the summer, and a continuous supply of fresh air to the room. Total heat exchanger is an energy loss due to ventilation means for recovering energy. Features excellent energy efficiency: using cellular runner recovered within a large surface area for the air flow pattern, with high heat exchange efficiency characteristics prevent odor transfer of special effects: using almost no odor adsorption ion exchange resin latent heat (wet gas) exchange adsorbent used, and the use of silica gel as an absorbent material as compared to the possibility of transfer and accumulation of odor is reduced to the minimum limit. Washable: Normally, cleaning is recommended to use air purge runner, but in the long use of contaminated circumstances, may be washed with water and air leaks less: around part of the unit and the special sealing material combinations runner dehumidifier unit, After long-term use, it can still maintain its high degree of tightness. ◆ design diversity fresh air heat recovery unit ◆ Stand-alone hybrid wind single stand-alone heat recovery unit heat recovery unit: focus on fresh air heat recovery process. ◆ fresh air heat recovery unit ◆ modular hybrid wind combined heat recovery unit combined heat recovery characteristics: can focus on fresh air after the heat recovery process mix, and then cooling, heating, humidification, purification and other functions, can achieve integration design. Rotary dehumidification unit _ units _ air conditioning units, dehumidifiers supplied by wucheng Dingrui Air Conditioning Equipment Co., Ltd. Wucheng Dingrui Air Conditioning Equipment Co., Ltd. (www.wcdrkt.com) (www.wcdrkt.com) strong, credible, Shandong Texas fan, ventilation equipment industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead Dingrui into the brilliant air conditioning and you work for a better future! |
Admin>>>
You are the 31696 visitor
Copyright © GuangDong ICP No. 10089450, Wu Cheng Ding Rui Air Conditioning Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 31696 visitor
Copyright © GuangDong ICP No. 10089450, Wu Cheng Ding Rui Air Conditioning Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility